<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">ophthalmology</journal-id><journal-title-group><journal-title xml:lang="ru">Офтальмология</journal-title><trans-title-group xml:lang="en"><trans-title>Ophthalmology in Russia</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1816-5095</issn><issn pub-type="epub">2500-0845</issn><publisher><publisher-name>Ophthalmology</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.18008/1816-5095-2018-2S-145-152</article-id><article-id custom-type="elpub" pub-id-type="custom">ophthalmology-641</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ХИРУРГИЯ КАТАРАКТЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>CATARACT SURGERY</subject></subj-group></article-categories><title-group><article-title>Сравнение плотности эндотелиальных клеток роговицы после факоэмульсификации плотной катаракты с использованием комбинированного ультразвука и торсионного ультразвука с Intelligent Phaco</article-title><trans-title-group xml:lang="en"><trans-title>Comparison of Cornea Endothelial Cells Density the After Aspiration of Dense Cataracts using Two Variants of Phacoemulsification Parameters</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шухаев</surname><given-names>С. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Shukhaev</surname><given-names>S. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>врач-офтальмолог,</p><p>ул. Ярослава Гашека, 21, Санкт-Петербург, 192071</p></bio><bio xml:lang="en"><p>ophthalmologist,</p><p>Gashek str., 21, Saint Petersburg, 192071</p></bio><email xlink:type="simple">shukhaevsv@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Бойко</surname><given-names>Э. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Boiko</surname><given-names>E. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>доктор медицинских наук профессор, директор филиала,</p><p>ул. Ярослава Гашека, 21, Санкт-Петербург, 192071</p></bio><bio xml:lang="en"><p>MD, PhD, professor, director,</p><p>Gashek str., 21, Saint Petersburg, 192071</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Санкт-Петербургский филиал ФГАУ «МНТК “Микрохирургия глаза” имени академика С.Н. Федорова» Министерства здравоохранения Российской Федерации</institution><country>Россия</country></aff><aff xml:lang="en"><institution>The Saint Petersburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>28</day><month>07</month><year>2018</year></pub-date><volume>15</volume><issue>2S</issue><fpage>145</fpage><lpage>152</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Шухаев С.В., Бойко Э.В., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Шухаев С.В., Бойко Э.В.</copyright-holder><copyright-holder xml:lang="en">Shukhaev S.V., Boiko E.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.ophthalmojournal.com/opht/article/view/641">https://www.ophthalmojournal.com/opht/article/view/641</self-uri><abstract><sec><title>Цель</title><p>Цель: выбрать из двух вариантов настроек факоэмульсификатора (комбинированный УЗ и торсионный УЗ с Intelligent Phaco (IP)) более безопасный в отношении сохранения эндотелиальных клеток роговицы и уменьшения послеоперационных осложнений.</p></sec><sec><title>Пациенты и методы</title><p>Пациенты и методы. 72 пациентам была выполнена факоэмульсификация с имплантацией ИОЛ. Пациенты случайным образом были разделены на две группы (основная n = 33 и контрольная n = 39). На этапе аспирации фрагментов хрусталика в основной группе использовали комбинированный УЗ, в контрольной группе — торсионный УЗ с IP. Подсчет эндотелиальных клеток и другие исследования были проведены через 1 день, 1 неделю и 6 месяцев после операции.</p></sec><sec><title>Результаты</title><p>Результаты. Острота зрения с коррекцией вдаль в исследуемых группах через 1 неделю после операции была сходной: в основной группе — 0,813 ± 0,228, в контрольной — 0,765 ± 0,250. Статистически достоверной разницы в толщине роговицы между группами не отмечено: в основной группе — 533,48 ± 12,41, в контрольной — 536,44 ± 10,92. В то же время относительно плотности эндотелиальных клеток была выявлена статистически достоверная разница: в основной группе — 1871,30 ± 187,41 (через 1 неделю), 1865 ± 178,9 (через 6 месяцев); в контрольной — 1809,63 ± 225,43 (через 1 неделю), 1791 ± 230,82 (через 6 месяцев). Процент потери эндотелиальных клеток оказался, соответственно, более низким в основной группе во все сроки наблюдения после операции: 3,90% (через 1 день), 4,54% (через 1 неделю), 4,9% (через 6 месяцев). В контрольной группе: 7,71% (через 1 день), 9,25% (через 1 неделю), 10,4% (через 6 месяцев).</p></sec><sec><title>Заключение</title><p>Заключение. Данные исследования показали преимущества комбинированного УЗ по сравнению с торсионным УЗ с IP при аспирации плотного хрусталика. Благодаря меньшему расходу УЗ энергии и более высокой скорости аспирации фрагментов комбинированный УЗ позволяет уменьшить потерю эндотелиальных клеток роговицы и снизить количество и выраженность связанных с ней послеоперационных осложнений. </p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Purpose</title><p>Purpose: to compare two types of phacoemulsification parameters (combination ultrasound and torsional US with IP) with estimating the number of postoperative complications caused by intraoperative trauma of corneal endothelial cells.</p></sec><sec><title>Patients and methods</title><p>Patients and methods. 72 patients underwent phacoemulsification with IOL implantation. Patients were randomly divided into two groups (main n = 33 and control n = 39). During the aspiration of lens fragments in the main group the combination ultrasound was used, while torsional US with IP was used in the control group. Endothelial cell counting and other examinations were performed 1 day, 1 week and 6 months after the surgery.</p></sec><sec><title>Results</title><p>Results. CDVA in the explored groups 1 week after the surgery was similar: the main group — 0.813 ± 0.228, the control group — 0.765 ± 0.250, There was also no statistically significant difference in the thickness of the cornea between the groups: the main group — 533.48 ± 12.41, the control group — 536.44 ± 10.92. At the same time, a statistically significant difference was found in the density of endothelial cells: the main group: 1871.30 ± 187.41 (after 1 week), 1865 ± 178.9 (after 6 months); control group: 1809.63 ± 225.43 (after 1 week), 1791 ± 230.82 (after 6 months). The percentage of cell loss was, respectively, lower in the main group at all times of observation: 3.90% (after 1 day), 4.54% (after 1 week), 4.9% (after 6 months). In the control group: 7.71% (after 1 day), 9.25% (after 1 week), 10.4% (after 6 months).</p></sec><sec><title>Conclusions</title><p>Conclusions. Data obtained in this study has showed the advantages of combination ultrasound in comparison with torsional US with IP, when performing aspiration of dense lenses. Due to lower consumption of ultrasound energy and higher aspiration rate of the fragments, combination ultrasound can reduce the loss of corneal endothelial cells and decrease the number and severity of postoperative complications associated with it. </p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>факоэмульсификация катаракты</kwd><kwd>комбинированный ультразвук</kwd><kwd>торсионный ультразвук с IP</kwd><kwd>плотность эндотелиальных клеток</kwd><kwd>плотный хрусталик</kwd><kwd>послеоперационная кератопатия</kwd></kwd-group><kwd-group xml:lang="en"><kwd>phacoemulsification of cataract</kwd><kwd>combination ultrasound</kwd><kwd>torsional ultrasound with IP</kwd><kwd>endothelial cell density</kwd><kwd>dense lens</kwd><kwd>postoperative keratopathy</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Азнабаев Б.М. Ультразвуковая хирургия катаракты — факоэмульсификация. Mосква: Август; 2005:136. [Aznabaev B.M. Ultrasound cataract surgery — phacoemulsification. Moscow: August; 2005:136. (In Russ)]</mixed-citation><mixed-citation xml:lang="en">Азнабаев Б.М. Ультразвуковая хирургия катаракты — факоэмульсификация. Mосква: Август; 2005:136. [Aznabaev B.M. Ultrasound cataract surgery — phacoemulsification. Moscow: August; 2005:136. (In Russ)]</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Буратто Л. Хирургия катаракты. Переход от экстракапсулярной экстракции катаракты к факоэмульсификации. Москва: Fabiano; 1999:474. [Buratto L. Cataract surgery. Transition from extracapsular extraction of cataract to phacoemulsification. Moscow: Fabiano; 1999:474. (In Russ)]</mixed-citation><mixed-citation xml:lang="en">Буратто Л. Хирургия катаракты. Переход от экстракапсулярной экстракции катаракты к факоэмульсификации. Москва: Fabiano; 1999:474. [Buratto L. Cataract surgery. Transition from extracapsular extraction of cataract to phacoemulsification. Moscow: Fabiano; 1999:474. (In Russ)]</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Kelman C.D. Phaco-emulsification and aspiration. A new technique of cataract removal. A preliminary report. Am J Ophthalmol. 1967;64(1):23–35. DOI: 10.1016/0002-9394(67)93340-5</mixed-citation><mixed-citation xml:lang="en">Kelman C.D. Phaco-emulsification and aspiration. A new technique of cataract removal. A preliminary report. Am J Ophthalmol. 1967;64(1):23–35. DOI: 10.1016/0002-9394(67)93340-5</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Singh R., Vasavada A.R., Janaswamy G. Phacoemulsification of brunescent and black cataracts. J Cataract Refract Surg. 2001 Nov;27(11):1762–9. DOI: 10.1016/ S0886-3350(01)00839-2</mixed-citation><mixed-citation xml:lang="en">Singh R., Vasavada A.R., Janaswamy G. Phacoemulsification of brunescent and black cataracts. J Cataract Refract Surg. 2001 Nov;27(11):1762–9. DOI: 10.1016/ S0886-3350(01)00839-2</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Jun B., Berdahl J.P., Kim T. Thermal study of longitudinal and torsional ultrasound phacoemulsification: tracking the temperature of the corneal surface, incision, and handpiece. J Cataract Refract Surg. 2010 May;36(5):832–7. DOI: 10.1016/j. jcrs.2009.11.015</mixed-citation><mixed-citation xml:lang="en">Jun B., Berdahl J.P., Kim T. Thermal study of longitudinal and torsional ultrasound phacoemulsification: tracking the temperature of the corneal surface, incision, and handpiece. J Cataract Refract Surg. 2010 May;36(5):832–7. DOI: 10.1016/j. jcrs.2009.11.015</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Zeng M., Liu X., Liu Y., Xia Y., Luo L., Yuan Z., Zeng Y., Liu Y. Torsional ultrasound modality for hard nucleus phacoemulsification cataract extraction. Br J Ophthalmol. 2008 Aug;92(8):1092-6, Epub 2008 Jun 20. DOI: 10.1136/bjo.2007.128504</mixed-citation><mixed-citation xml:lang="en">Zeng M., Liu X., Liu Y., Xia Y., Luo L., Yuan Z., Zeng Y., Liu Y. Torsional ultrasound modality for hard nucleus phacoemulsification cataract extraction. Br J Ophthalmol. 2008 Aug;92(8):1092-6, Epub 2008 Jun 20. DOI: 10.1136/bjo.2007.128504</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Wang Y., Xia Y., Zeng M., Liu X., Luo L., Chen B., Liu Y., Liu Y. Torsional ultrasound efficiency under different vacuum levels in different degrees of nuclear cataract. J Cataract Refract Surg. 2009 Nov;35(11):1941–5. DOI: 10.1016/j.jcrs.2009.05.055</mixed-citation><mixed-citation xml:lang="en">Wang Y., Xia Y., Zeng M., Liu X., Luo L., Chen B., Liu Y., Liu Y. Torsional ultrasound efficiency under different vacuum levels in different degrees of nuclear cataract. J Cataract Refract Surg. 2009 Nov;35(11):1941–5. DOI: 10.1016/j.jcrs.2009.05.055</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Fakhry M.A., Shazly M.I. Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract. Clin Ophthalmol. 2011;5:973–8. Epub 2011 Jul 15. DOI: 10.2147/OPTH.S22879</mixed-citation><mixed-citation xml:lang="en">Fakhry M.A., Shazly M.I. Torsional ultrasound mode versus combined torsional and conventional ultrasound mode phacoemulsification for eyes with hard cataract. Clin Ophthalmol. 2011;5:973–8. Epub 2011 Jul 15. DOI: 10.2147/OPTH.S22879</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Sippel K.C., Pineda R. Jr. Phacoemulsification and thermal wound injury. Semin Ophthalmol. 2002 Sep-Dec;17(3–4):102–9.</mixed-citation><mixed-citation xml:lang="en">Sippel K.C., Pineda R. Jr. Phacoemulsification and thermal wound injury. Semin Ophthalmol. 2002 Sep-Dec;17(3–4):102–9.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Nagy Z.Z., Takacs A.I., Filkorn T., Kránitz K., Gyenes A., Juhász É., Sándor G.L., Kovacs I., Juhász T., Slade S. Complications of femtosecond laser-assisted cataract surgery. J Cataract Refract Surg. 2014 Jan;40(1):20–8. DOI: 10.1016/j.jcrs.2013.08.046</mixed-citation><mixed-citation xml:lang="en">Nagy Z.Z., Takacs A.I., Filkorn T., Kránitz K., Gyenes A., Juhász É., Sándor G.L., Kovacs I., Juhász T., Slade S. Complications of femtosecond laser-assisted cataract surgery. J Cataract Refract Surg. 2014 Jan;40(1):20–8. DOI: 10.1016/j.jcrs.2013.08.046</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Астахов С.Ю. Кератопатия после факоэмульсификации. Новое в офтальмологии. 2014;3. [Astahov S.Y. Keratopathy after phacoemulsification. New in ophthalmology=Novoe v oftal’mologii. 2014;3. (In Russ)]</mixed-citation><mixed-citation xml:lang="en">Астахов С.Ю. Кератопатия после факоэмульсификации. Новое в офтальмологии. 2014;3. [Astahov S.Y. Keratopathy after phacoemulsification. New in ophthalmology=Novoe v oftal’mologii. 2014;3. (In Russ)]</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Копаев С.Ю., Борзенок С.А., Копаева В.Г., Алборова В.У. Состояние заднего эпителия роговицы после лазерной и ультразвуковой факофрагментации. электронно-микроскопическое исследование в эксперименте. Сообщение 3. Офтальмохирургия. 2014;(2):6–9. Kopayev S.Y., Borzenok S.A., Kopayeva V.G., Alborova V.U. Corneal endothelium cells response after laser and ultrasound phacofragmentation. electron microscopy in experiment. Report 3. Fyodorov Journal of Ophthalmic Surgery=Oftal’mokhirurgiya. 2014;(2):6–9. (in Russ.)] DOI: 10.25276/0235-4160-2014-2-6-9</mixed-citation><mixed-citation xml:lang="en">Копаев С.Ю., Борзенок С.А., Копаева В.Г., Алборова В.У. Состояние заднего эпителия роговицы после лазерной и ультразвуковой факофрагментации. электронно-микроскопическое исследование в эксперименте. Сообщение 3. Офтальмохирургия. 2014;(2):6–9. Kopayev S.Y., Borzenok S.A., Kopayeva V.G., Alborova V.U. Corneal endothelium cells response after laser and ultrasound phacofragmentation. electron microscopy in experiment. Report 3. Fyodorov Journal of Ophthalmic Surgery=Oftal’mokhirurgiya. 2014;(2):6–9. (in Russ.)] DOI: 10.25276/0235-4160-2014-2-6-9</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Майчук Д.Ю. Асептические реакции при хирургии катаракты. Российская офтальмология онлайн. № 11. [Maychuk D.Y. Aseptic reactions in cataract surgery. Russian ophthalmology online. № 11. URL: http://www.eyepress.ru/article. aspx?11931</mixed-citation><mixed-citation xml:lang="en">Майчук Д.Ю. Асептические реакции при хирургии катаракты. Российская офтальмология онлайн. № 11. [Maychuk D.Y. Aseptic reactions in cataract surgery. Russian ophthalmology online. № 11. URL: http://www.eyepress.ru/article. aspx?11931</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Иошин И.Э., Хачатрян Г.Т., Оздербаева А.А. Анализ результатов применения технологии Ozil IP при факоэмульсификации катаракты высокой плотности. Офтальмохирургия. 2011;2:59–63. [Ioshin I.E., Khachatryan G.T., Ozderbaeva A.A. Analysis of the results of application of Ozil IP technology in phacoemulsification of high density cataract. Fyodorov Journal of Ophthalmic Surgery=Oftal’mokhirurgiya. 2011;2:59–63. (In Russ)]</mixed-citation><mixed-citation xml:lang="en">Иошин И.Э., Хачатрян Г.Т., Оздербаева А.А. Анализ результатов применения технологии Ozil IP при факоэмульсификации катаракты высокой плотности. Офтальмохирургия. 2011;2:59–63. [Ioshin I.E., Khachatryan G.T., Ozderbaeva A.A. Analysis of the results of application of Ozil IP technology in phacoemulsification of high density cataract. Fyodorov Journal of Ophthalmic Surgery=Oftal’mokhirurgiya. 2011;2:59–63. (In Russ)]</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Tomilova E., Shukhaev S. A novel method to compare phacoemulsification parameters in vivo: two halves of one nucleus. Graefes Arch Clin Exp Ophthalmol. 2016 Aug;254(8):1579–84. DOI: 10.1007/s00417-016-3376-0</mixed-citation><mixed-citation xml:lang="en">Tomilova E., Shukhaev S. A novel method to compare phacoemulsification parameters in vivo: two halves of one nucleus. Graefes Arch Clin Exp Ophthalmol. 2016 Aug;254(8):1579–84. DOI: 10.1007/s00417-016-3376-0</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Трубилин В.Н., Ильинская И.А., Копаев С.Ю. Достоверность показателей приборов, измеряющих геометрические параметры роговицы. Офтальмохирургия. 2014;(4):50–54. [Trubilin V.N., Il´inskaya I.A., Kopayev S.Y. Reliability of indicators of devices measuring geometric parameters of cornea. Fyodorov Journal of Ophthalmic Surgery=Oftal’mokhirurgiya. 2014;(4):50–54. (In Russ.)] DOI: 10.25276/0235-4160-2014-4-50-54</mixed-citation><mixed-citation xml:lang="en">Трубилин В.Н., Ильинская И.А., Копаев С.Ю. Достоверность показателей приборов, измеряющих геометрические параметры роговицы. Офтальмохирургия. 2014;(4):50–54. [Trubilin V.N., Il´inskaya I.A., Kopayev S.Y. Reliability of indicators of devices measuring geometric parameters of cornea. Fyodorov Journal of Ophthalmic Surgery=Oftal’mokhirurgiya. 2014;(4):50–54. (In Russ.)] DOI: 10.25276/0235-4160-2014-4-50-54</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Cionni R.J., Crandall A.S., Felsted D. Length and frequency of intraoperative occlusive events with new torsional phacoemulsification software. J Cataract Refract Surg. 2011 Aug 18. DOI: 10.1016/j.jcrs.2011.04.027</mixed-citation><mixed-citation xml:lang="en">Cionni R.J., Crandall A.S., Felsted D. Length and frequency of intraoperative occlusive events with new torsional phacoemulsification software. J Cataract Refract Surg. 2011 Aug 18. DOI: 10.1016/j.jcrs.2011.04.027</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Ratnarajan G., Packard R., Ward M. Combined occlusion-triggered longitudinal and torsional phacoemulsification during coaxial microincision cataract surgery: effect on 30-degree mini-flared tip behavior. J Cataract Refract Surg. 2011 May;37(5):825– 9. Epub 2011 Mar 25. DOI: .10.1016/j.jcrs.2010.11.038</mixed-citation><mixed-citation xml:lang="en">Ratnarajan G., Packard R., Ward M. Combined occlusion-triggered longitudinal and torsional phacoemulsification during coaxial microincision cataract surgery: effect on 30-degree mini-flared tip behavior. J Cataract Refract Surg. 2011 May;37(5):825– 9. Epub 2011 Mar 25. DOI: .10.1016/j.jcrs.2010.11.038</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
