Preview

Ophthalmology in Russia

Advanced search

Experience of Using Corneal Epithelium Protector Gel for the Treatment of Corneal Erosion for a Patient after Radial Keratotomy

https://doi.org/10.18008/1816-5095-2022-2-441-443

Abstract

Currently, one of the actual problems of pharmacotherapy is the treatment of recurrent corneal erosions. Traumatic and postoperative damage to the cornea can disrupt the connection between the basement membrane and the epithelium. One type of such predisposing factors that disrupt the connection between the epithelium and the basement membrane is a previously performed anterior radial keratotomy. This article describes a clinical case using off-label “Protector of corneal epithelial SPHERO®oko gel” within the complex treatment of traumatic corneal erosion for a patient after radial keratotomy. A conservative treatment includes applying 5 % dexpanthenol gel, 0.05 % picloxidine solution, a tear substitute and Corneal Epithelium Protector (BIOMIR Service, Russia) 4 times a day until the erosion was closed and then again during 2 weeks. On the 14th day complete epithelization of the cornea was achieved. Within 2 weeks the condition remained stable. Protector of corneal epithelial showed its effectiveness in complex treatment of traumatic corneal erosion for a patient after radial keratotomy. 

About the Author

A. S. Semakina
Eye Clinic SPECTR
Russian Federation

PhD, ophthalmologist, ophthalmosurger,

Berezovaya Roshcha passage, 12, Moscow, 125252



References

1. Kanyukov V.N., Stadnikov A.A., Trubina O.M., Yahina O.M. Application of bioplastic material “Hiamatrix” in diseases of the cornea.. Annals of Orenburg State University = Vestnik Orenburgskogo gosudarstvennogo universiteta. 2013;4:243–235 (In Russ.).

2. Pfister R. The normal surface of corneal epithelium: a scanning electron microscopic study. Invest. Ophthalmol. (Copenh). 1973;12(9):654–668.

3. Sonnenberg A., Calafat J., Janssen H. Integrin a6/b4 complex is located in hemidesmosomes, suggesting a major role in epidermal cell-basement membrane adhesion. J. Cell. Biol. 1991;113:907–917. DOI: 10.1083/jcb.113.4.907

4. Wood T. Reccurrent erosion. Tr. Am. Ophth. Soc. 1984;LXXXII:850–898.

5. Boudreau N., Sympson C., Werb Z. Suppression of ICE and apoptosis in mammary epithelial cells by extracellular matrix. Science. 1995;267:891–893. DOI: 10.1126/science.7531366

6. Boudreau N., Werb Z., Bissell M. Suppression of apoptosis by basement membrane requires three-dimensional tissue organization and withdrawal from the cell cycle. Proc. Natl. Acad. Sci. USA. 1996;93:3500–3513. DOI: 10.1073/pnas.93.8.3509

7. Fujikawa L., Foster C., Gipson I., Colvin R. Basement membrane components in healing rabbit corneal epithelial wounds: immunofluorescence and ultrastructural studies. J. Cell. Biol. 1984;98(1):128–138. DOI: 10.1083/jcb.98.1.128

8. Tripathi R., Bron A. Ultrastructural study of non-traumatic recurrent corneal erosion. Br. J. Ophthalmol. 1972;56:73–85. DOI: 10.1136/bjo.56.2.73

9. Volkov V.V., Dal’ G.A., Tulina V.M., Kulikov B.C., Gavrilova N.K., Nikolaenko V.P. Contusion ruptures of the eye capsule along postoperative corneal-limbal scars.. Annals of Ophthalmology = Vestnik oftal’mologii. 1998;114(2):17–20 (In Russ.).

10. Malyugin B.E., Panteleev E.N., Bessarabov A.N., Semakina A.S. Carrying out a corneal tunnel incision in patients after radial keratotomy with phacoemulsification. Modern technologies in ophthalmology = Sovremennye tekhnologii v oftal’mologii. 2019;5:121–124 (In Russ.). DOI: 10.25276/2312-4911-20195-121-124

11. Horoshilova-Maslova I.P., Andreeva V.P., Ilatovskaya L.V., Kuznecova I.A. Clinical and histopathological examination of enucleated eyes with contusion rupture of the cornea after radial keratotomy. Modern technologies in ophthalmology = Sovremennye tekhnologii v oftal’mologii.1998;114(4):3–8 (In Russ.).

12. McNeill J.I. Corneal incision dehiscence during penetrating keratoplasty nine years after radial keratotomy. J Cataract Refract Surg. 1993;19(4):542–543. DOI: 10.1016/s0886-3350(13)80620-7

13. Perova N.V., Porunova Yu.V., Ur’yash V.F., Faminskaya L.A. Biodegradable collagen-containing matrix SferogelTM for cell transplantation. Promising Materials = Perspektivnye materialy. 2004;2:52– 59 (In Russ.).

14. Sevast’yanov V.I., Perova N.V. SperoGel is an injectable biodegradable implant for replacement and regenerative medicine. Practical medicine = Prakticheskaya meditsina. 2014;8(84):110–116 (In Russ.).

15. Pronkin I.A., Majchuk D.Yu. Recurrent corneal erosion: etiology, pathogenesis, methods of diagnosis and treatment. Fyodorov Journal of Ophthalmic Surgery = Oftal’mokhirurgiya. 2015;1:62–67 (In Russ.).

16. Teng C. Fine structure of the human cornea: epithelium and stroma. Am. J. Ophthalmol. 1962;19;1094–1097.

17. Latessa A., Teng C., Katzin H. The hystochemistry of the basement membrane of the cornea. Am. J. Ophthalmol. 1954;38(2):171–177.

18. Khodadoust A., Silverstein A., Kenyon K. Adhesion of regenerating corneal epithelium: the role of basement membrane. Am. J. Ophthalmol. 1968;57:311–317.


Review

For citations:


Semakina A.S. Experience of Using Corneal Epithelium Protector Gel for the Treatment of Corneal Erosion for a Patient after Radial Keratotomy. Ophthalmology in Russia. 2022;19(2):441-443. (In Russ.) https://doi.org/10.18008/1816-5095-2022-2-441-443

Views: 566


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1816-5095 (Print)
ISSN 2500-0845 (Online)