Purpose. To assess refractive result of phacoemulsification (PE) with capsular tension ring (CTR) implantation.
Patients and methods. In total, 37 eyes of 37 patients who underwent PE with intraocular lens (IOL) implantation were divided into 2 groups: study group (n = 18) with CTR implantation and control group (n = 19) without CTR. Optical biometry (IOL-Master 500) was performed for each patient before PE. Barrett Universal II Formula was used for IOL calculation. IOL power calculation error was assessed by comparing target refraction and final refraction measured by Topcon-8800 autorefractometer 1 month after surgery.
Results. Despite almost identical preoperative values in both groups refractive result was different. Patients with CTR implantation had more hyperopic IOL power calculation error of +0.41 ± 0.52 D versus — 0.02 ± 0.54 D in the control group (p = 0.037). Refractive result in control group was more predictable (mean absolute error was 0.55 ± 0.34 D and 0.41 ± 0.30 D for groups respectively, p = 0.180).
Conclusion. CTR implantation could help surgeon to perform PE in complicated cases. Nevertheless, CTR implantation could leads to hyperopic shift. To avoid refractive errors optimized A-constants could be used (118.85 for AcrySof SA60AT and 118.47 for Akreos Adapt AO).
About the Authors
D. F. BelovRussian Federation
ophthalmologist,
Uchebniy lane, 5, Saint-Petersburg, 194354
V. P. Nikolaenko
Russian Federation
MD, Professor of the Department of otorhinolaryngology and ophthalmology, Uchebniy lane, 5, Saint-Petersburg, 194354;
deputy chief physician of ophthalmology, University Emb., 7/9, Saint-Petersburg, 199034
References
1. Oudjani N., Renault D., Courrier E., Malek Y. Phacoemulsification and zonular weakness: contribution of the capsular tension ring with a thread. Clin Ophthalmol. 2019 Dec 11;13:2301–2304. DOI: 10.2147/OPTH.S212063
2. Hemalatha B.C., Shetty S.B. Analysis of intraoperative and postoperative complications in pseudoexfoliation eyes undergoing cataract surgery. J Clin Diagn Res. 2016 Apr;10(4):NC05-8. DOI: 10.7860/JCDR/2016/17548.7545
3. Om Parkash R., Mahajan S., Om Parkash T., Om Parkash T., Rai M. Nuclear scaffold: three-dimensional indigenous capsular bag support combined with IOL scaffold and capsular tension ring to prevent posterior capsule rupture in zonulopathy. J Cataract Refract Surg. 2019 Dec;45(12):1696–1700. DOI: 10.1016/j.jcrs.2019.08.046
4. Jacob S., Agarwal A., Agarwal A., Agarwal S., Patel N., Lal V. Efficacy of a capsular tension ring for phacoemulsification in eyes with zonular dialysis. J Cataract Refract Surg. 2003 Feb;29(2):315–321. DOI: 10.1016/s0886-3350(02)01534-1 5. Hara T., Hara T, Yamada Y. “Equator Ring” for Maintenance of the Completely Circular Contour of the Capsular Bag Equator After Cataract Removal. Ophthalmic Surg. 1991 Jun;22(6):358–359.
5. Malyugin B.E., Golovin A.V., Uzunyan D.G., Isaev M.A. Microincisional phacoemulsification with the modified capsular tension ring in patients with zonular dialysis. Fyodorov Journal of Ophthalmic Surgery = Oftal’mokhirurgiya. 2011;3:22–26 (In Russ.).
6. Potemkin V.V., Ageeva E.V. Zonular instability in patients with pseudoexfoliative syndrome: the analysis of 1000 consecutive phacoemulsifications. Ophthalmology Journal = Oftal’mologicheskie vedomosti. 2018;11(1):41–46 (In Russ.). DOI: 10.17816/OV11141-46
7. Lanzl I.M., Merté R.L., Graham A.D. Does head positioning influence anterior chamber depth in pseudoexfoliation syndrome? J Glaucoma. 2000 Jun;9(3):214– 218. DOI: 10.1097/00061198-200006000-00003
8. Kim J.J., Moon J.H., Jeong H.S., Chi M. Has decreased visual acuity associated with blunt trauma at the emergency department recovered? J Craniofac Surg. 2012 May;23(3):630–633. DOI: 10.1097/SCS.0b013e31824db77a
9. Gale R.P., Saldana M., Johnston R.L., Zuberbuhler B., McKibbin M. Benchmark standards for refractive outcomes after NHS cataract surgery. Eye (Lond). 2009 Jan;23(1):149–152. DOI: 10.1038/sj.eye.6702954
10. Melles R.B., Holladay J.T., Chang W.J. Accuracy of intraocular lens calculation formulas. Ophthalmology. 2018 Feb;125(2):169–178. DOI: 10.1016/j.ophtha.2017.08.027
11. Celik E., Koklu B., Dogan E., Erdogan G., Alagoz G. Indications and clinical outcomes of capsular tension ring implantation in phacoemulsification surgery at a tertiary teaching hospital: A review of 4316 cataract surgeries. J Fr Ophtalmol. 2015 Dec;38(10):955–959. DOI: 10.1016/j.jfo.2015.05.007
12. Tribus C., Alge C.S., Haritoglou C., Lackerbauer C., Kampik A., Mueller A., Priglinger S.G. Indications and clinical outcome of capsular tension ring (CTR) implantation: A review of 9528 cataract surgeries. Clin Ophthalmol. 2007 Mar;1(1):65–69.
13. Wang B.Z., Chan E., Vajpayee R.B. A retrospective study of the indications and outcomes of capsular tension ring insertion during cataract surgery at a tertiary teaching hospital. Clin Ophthalmol. 2013;7:567–572. DOI: 10.2147/OPTH.S38543
Review
For citations:
Belov D.F., Nikolaenko V.P. Effect of Capsular Tension Ring Implantation during Phacoemulsification on Postoperative Refraction. Ophthalmology in Russia. 2022;19(3):489-492. (In Russ.) https://doi.org/10.18008/1816-5095-2022-3-489-492