Preview

Ophthalmology in Russia

Advanced search

Cataract Surgery Results of New Lens Implantation “Synthesis”

https://doi.org/10.18008/1816-5095-2022-4-753-758

Abstract

Purpose. Analysis of the cataract surgery visual outcomes and advantages of intraocular lens Synthesis SIPY.

Material and methods. We have operated 43 eyes with cataract (38 patients) using Synthesis SIPY lens. Non-corrected visual acuity was 0.13 ± 0.08, best corrected visual acuity (BCVA) was 0.36 ± 0.1.

Results. Following 7 months, secondary cataract was not detected in any patient, what explain the actuality of square edge optical part on 360° of perimeter. The lens is inserted in cartridge in factory sterile conditions which exclude the contact between lens and environment, reduce the risk of incorrect inserting of the lens in cartridge following pinching by the cartridge flaps and, subsequently, the haptic tearing off. This complex “lens-cartridge” excludes the damage of haptics and optic parts, which can occur in using other IOLs during the removal of the lens from the vial and placing it in the groove of the cartridge. Position of cartridge in injector centralizes the cartridge tunnel for the Accuject Pro injector plunger, thereby reducing the risk of pinching the rubber tip of the IOL haptic plunger during implantation. The diameter of the cartridge tip allows the IOL to be implanted through a 1.6 mm tunnel. The uncorrected visual acuity after surgery was 0.6 ± 0.28. The best corrected visual acuity was 0.78 ± 0.24.

Conclusions. The Synthesis SIPY lens has a number of advantages: factory installation of the lens into the cartridge and compatibility of the cartridge with the Accuject Pro injector prevent damage to the IOL; Implantation of the Synthesis SIPY lens is possible through the 1.6 mm corneal tunnel; high diopter ranges from -10.0D to + 40.0D allows for maximum visual results.

About the Authors

E. A. Ivachev
Departmental Clinical Hospital at the station Penza of JSC “Russian Railways”; Medical Institute, Penza State University
Russian Federation

PhD, ophthalmologist, head of Ophthalmology department

Uritskogo str., 118, Penza, 440600, Russian Federation

Krasnaya str., 40, Penza, 440026, Russian Federation 



I. P. Denisova
Departmental Clinical Hospital at the station Penza of JSC “Russian Railways”
Russian Federation

ophthalmologist

Uritskogo str., 118, Penza, 440600, Russian Federation 



E. V. Anisimova
Departmental Clinical Hospital at the station Penza of JSC “Russian Railways”
Russian Federation

ophthalmologist

Uritskogo str., 118, Penza, 440600, Russian Federation 



A. Yu. Krasnova
Medical Institute, Penza State University
Russian Federation

resident of Ophthalmology department

Krasnaya str., 40, Penza, 440026, Russian Federation 



References

1. Shukhaev S.V., Kirillova O.V., Zagorulko A.M. Comparative evaluation of target refraction between three monofocal flexible intraocular lenses. Fyodorov Journal of Ophthalmic Surgery = Oftal’mokhirurgiya. 2018;1:53–58 (In Russ.)]. DOI: 10.25276/0235-4160-2018-1-53-58

2. Anisimova N.S., Anisimov S.I., Anisimova S.Y. The variety of secondary changes of the posterior capsule of the lens after the implantation of different types of IOLs. Fyodorov Journal of Ophthalmic Surgery = Oftal’mokhirurgiya. 2015;2:6–11 (In Russ.).

3. Masket S. Truncated edge design, dysphotopsia, and inhibition of posterior capsule opacification. J. Cataract Refract. Surg. 2000;26(1):145–147. DOI: 10.1016/s0886-3350(99)00329-6

4. Sviridova M.B., Grinev A.G., Zherebtsova O.M., Kalinina E.V., Sobyanin N.A., Bachurikhin V.P. Results of an experimental and clinical study of a new hydrophobic intraocular lens for correction of aphakia and corneal astigmatism. Fyodorov Journal of Ophthalmic Surgery = Oftal’mokhirurgiya. 2020;3:12–18 (In Russ.).

5. Peyman G.A., Sloane H. Ultraviolet light absorbing pseudophacos. Am. Intraocular implant. Soc. J. 1982;8:57–60.

6. Mainster M.A. Intraocular lenses should block UV radiation and violet but not blue light. Arch Ophthalmol. 2005;123:550–555. DOI: 10.1001/archopht.123.4.550

7. Ong H.S. Subash M., Sandhu A., Wilkins M.R. Intraocular lens delivery characteristics of the preloaded AcrySof IQ SN60WS AcrySert injectable lens system. American Journal of Ophthalmology. 2013;156(1):77–81. DOI: 10.1016/j.ajo.2013.01.032

8. Borkenstein A.F.M. Evaluation of the preloaded Acrysert System for IOLs. ASCRS ASOA Congress, Chicago, Illinois. 2008.

9. Maliugin B.Е. State of the art cataract surgery and intraocular optical correction. Annals of Ophthalmology = Vestnik oftal’mologii. 2014;130(6):80–88 (In Russ.).


Review

For citations:


Ivachev E.A., Denisova I.P., Anisimova E.V., Krasnova A.Yu. Cataract Surgery Results of New Lens Implantation “Synthesis”. Ophthalmology in Russia. 2022;19(4):753-758. (In Russ.) https://doi.org/10.18008/1816-5095-2022-4-753-758

Views: 1619


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1816-5095 (Print)
ISSN 2500-0845 (Online)