Purpose: Analysis of remote clinical functional results of high myopia correction in patients with thin cornea by method of intrastromal MyoRing implantation with Femtolaser assistance.
Materials and methods. 22 eyes of 22 patients were included into investigation, the мean age of patients was 30.20 ± 5.37 (from 24 to 40) years. Mean spherical equivalent (SE) of refraction was –11.52 ± 1.96 D, cylindrical component of refraction was –2.04 ± 1.64 D. Minimal pachymetry index in center was 491.6 ± 20.0 mkm. Corneal hysteresis (CH) was 8.60 ± 1.19 mm Hg. The average pupil diameter in mesopic conditions was 5.60 ± 0.23 mm. All patients had a history of mild amblyopia. Period of control in average 2 years.
Results. In 2 years after the surgery uncorrected visual acuity was 0.60 ± 1.22, corrected visual acuity 0.70 ± 0.20. Mean spherical equivalent (SE) of refraction was 0.61 ± 1.43 D, cylindrical component of refraction was –0.13 ± 0.50 D. Predictability of SE within ±0.5 D was 84 %, ±1.0 — 84 %. Index of safety was 1.16, index of efficacy — 1.0. CH was 9.50 ± 0.03 mm Hg. Mean pachymetry at center after the surgery did not change statistically significant in comparison with initial data (p = 1.00).
Conclusion. MyoRing implantation is an effective and safe method, it provides: refraction spherical component correction, astigmatism correction and CH increase (p = 0.01).
About the Authors
I. L. KulikovaRussian Federation
Kulikova Irina L. - MD, professor, deputy director for clinical work
Tractorostroiteley ave., 10, Cheboksary, 428028, Russian Federation
A. E. Terent’eva
Russian Federation
Terent’eva Anna E. - ophthalmologist
Tractorostroiteley ave., 10, Cheboksary, 428028, Russian Federation
M. V. Sinitsyn
Russian Federation
Sinitsyn Maksim V. - PhD, ophthalmologist, head of the Children’s department
Tractorostroiteley ave., 10, Cheboksary, 428028, Russian Federation
References
1. Moussa S., Dietrich M., Lenzhofer M., Ruckhofer J., Reitsameret H.A. Femtosecond laser in refractive corneal surgery. J Photochem Photobiol Sci. 2019;18(7):1669–1674. DOI: 10.1039/c9pp00039a
2. Shishkin S.A., Dutchin I.V., Sorokin E.L. A study of the thin cornea incidence among patients with varying degrees of myopia. Modern technologies in ophthalmology = Sovremennye tekhnologii v oftal’mologii. 2018;2:70–71 (In Russ.).
3. Daxer A. Corneal intrastromal implantation surgery for the treatment of moderate and high myopia. J Cataract Refract Surg. 2008;34(2):194–198. DOI: 10.1016/j.jcrs.2007.10.011
4. Rattan S.A. Continuous intracorneal ring implantation for treatment of myopic astigmatism. Int Med Case Rep J. 2018;11:217–220. DOI: 10.2147/IMCRJ.S173167
5. Pashtaev N.P., Pozdeeva N.A., Sinitsyn M.V., Shlenskaya O.V. Correction of high myopia in combination with a thin cornea using femtolaser intrastromal implantation of the MyoRing ring. Cataract and refractive surgery = Kataraktal’naya i refraktsionnaya khirurgiya. 2013;13(4):25–28 (In Russ.).
6. Alio J.L., Pinero D.P., Daxer A. Clinical outcomes after complete ring implantation in corneal ectasia sing the femtosecond technology: a pilot study. Ophthalmology. 2011;118(7):1282–1290. DOI: 10.1016/j.ophtha.2010.12.012
7. Daxer А. MyoRing treatment of myopia. J Optom. 2016;10(3):194–198. DOI: 10.1016/j.optom.2016.06.003
8. Studený P., Křížová D., Straňák Z., Kuchynka P. Clinical Results after Continuous Corneal ring (MyoRing) Implantation in Keratoconus Patients. Cesk. Slov. Oftalmol. 2015;71(1):87–90.
9. Khorrami Nejad M., Aghili O., Hashemian H., Aghazadeh Amiri M., Karimi F. Changes in Corneal Asphericity after MyoRing Implantation in Moderate and Severe Keratoconus. J Ophthalmic Vis Res. 2019 Oct 24;14(4):428 435. DOI: 10.18502/jovr.v14i4.5443.
10. Reinstein D.Z., Waring G.O. Graphic reporting of outcomes of refractive surgery. J Refract Surg. 2009;25(11):975–978. DOI: 10.3928/1081597X-20091016-01
11. Reinstein D.Z., Archer T.J., Randleman J.B. Mathematical model to compare the relative tensile strength of the cornea after PRK, LASIK and small incision lenticule extraction. J Refract Surg. 2013;29(7):454–460. DOI: 10.3928/1081597X-20130617-03
12. Daxer А. Biomechanics of the cornea. Int J Kerat Ectatic Cor Dis. 2014;3(2):57–62. DOI: 10.5005/jp-journals-10025-1080
13. Guell J.L., Rodriguesz Arenas A.F., Gris O., Malecaze F., Velasco F. Phacoemulsification of crystalline lens and implantation of intraocular lens for the correction of moderate and high myopia: 4 years follow up. J Cataract Refract Surg. 2003;29(1):34–38. DOI: 10.1016/s0886-3350(02)01944-2
14. Fernandez Vega L., Alfenso J.F., Villacamp T. Clear lens extraction for the correction of high myopia. Ophthalmology. 2003;110(12):2349–2354. DOI: 10.1016/S0161-6420(03)00794-2
15. Kohnen T., Knorz M.C., Cochener B., Gerl R.H., Arné J.L., Colin J., Alió J.L., Bellucci R., Marinho A. AcrySof phakic angle supported intraocular lens for the correction of moderate to high myopia: one year results of a multicenter European study. Ophthalmology. 2009;116(7):1314–1321. DOI: 10.1016/j.ophtha.2009.01.041
16. Toso A., Morselli S. Visual and aberrometric outcomes in eyes with an angle-supported phakic intraocular lens. J Cataract Refract Surg. 2012;38(9):1590–1594. DOI: 10.1016/j.jcrs.2012.04.038
17. Barsam A., Allan B.D. Excimer laser refractive surgery versus phakic intraocular lenses for the correction of moderate to high myopia. Cochrane Database Syst Rev. 2010;12(5):CD007679. DOI: 10.1002/14651858.CD007679.pub2
18. Alió J.L., Soria F., Abbouda A., Peña García P. Laser in situ keratomileusis for -6.00 to -18.00 diopters of myopia and up to -5.00 diopters of astigmatism: 15-year follow-up. J Cataract Refrac Surg. 2015;41(1):33–40. DOI: 10.1016/j.jcrs.2014.08.029
19. Pallikaris I.G., Kymionis G.D., Astyrakakis N.I. Corneal ectasia induced by laser in situ keratomileusis. J Cataract Refract Surg. 2001;27(11):1796–1802. DOI: 10.1016/s0886-3350(01)01090-2
20. Dilek Y., Ufuk Ü., Alper A., Yusuf Y., Burçin Kepez Y. Early Results with a New Posterior Chamber Phakic Intraocular Lens in Patients with High Myopia. J Ophthalmology. 2018:1329874. DOI: 10.1155/2018/1329874
Review
For citations:
Kulikova I.L., Terent’eva A.E., Sinitsyn M.V. Long-Term Clinical and Functional Results of High-Grade Myopia Correction by Intrastromal Implantation of the MyoRing Ring with Femtolaser Support. Ophthalmology in Russia. 2023;20(1):105-111. (In Russ.) https://doi.org/10.18008/1816-5095-2023-1-105-111