Preview

Ophthalmology in Russia

Advanced search

Influence of Intraocular Lens Material and Eye Axial Length on Posterior Capsule Opacification Dynamic Rate and Frequency

https://doi.org/10.18008/1816-5095-2016-4-247-251

Abstract

Purpose: To evaluate posterior capsule opacification (PCO) formation dynamic rate and frequency in artificial eyes with myopia in different terms after cataract extraction and it’s relation with IOL material. Patients and methods. An evaluation of PCO formation
dynamic rate and frequency was done by using a retrospective analysis of YAG-laser assist posterior capsule dissections in different terms after cataract extraction on 45640 eyes of 43520 patients with emmetropia and myopia without concomitant pathology.
The mean patient’s age was 73±7 years and the least follow-up after  hacoemulsification was 5 years. All eyes were divided on two groups. The first group included 25339 eyes where a hydrophilic IOL was implanted; the second group included 20301 eyes where a hydrophobic IOL was implanted. Results. At the first group the YAG-laser assist posterior capsule dissection was done on 2128 (8,4%) eyes. It was shown a proportional influence of axial length on PCO frequency but more rapidly the PCO rate increased between 26 to 28 mm and then this parameter had stabilization. The PCO dynamic rate had a normal statistical corresponding in the group with maximum at third postoperative year. At the second group YAG-laser assist posterior capsule dissection was done on 244 (1,2%) eyes. It was shown a proportional influence of axial length on PCO frequency too. But increasing of axial length more than 28 mm
increased PCO rate correspondingly that differ the second group from the first. The PCO dynamic rate had an inversely proportional character in the group. Comparing the PCO frequency in both groups showed that hydrophobic material has less PCO rate with any axial length and every time of follow-up. Conclusion. An IOL’s material plays an important role in PCO formation and PCO formation dynamic rate. Hydrophobic material has a statistically significant less PCO frequency through five-year follow-up in eyes with myopia and emmetropia. The PCO dynamic rate strongly differ between groups with a normal statistical corresponding in group 1 and inversely proportional in group 2.

About the Authors

G. V. Sorokoletov
S. Fyodorov Eye Microsurgery Federal State Institution
Russian Federation
PhD, ophthalmologist


V. K. Zuev
S. Fyodorov Eye Microsurgery Federal State Institution
Russian Federation
MD., professor, head of a department ‘lens surgery and intraocular
correction’


J. R. Tumanjan
S. Fyodorov Eye Microsurgery Federal State Institution
Russian Federation
MD, head of a department ‘past-graduated education’


F. M. Gerlyak
S. Fyodorov Eye Microsurgery Federal State Institution
Russian Federation
PhD, ophthalmologist


V. N. Veshhikova
S. Fyodorov Eye Microsurgery Federal State Institution
Russian Federation
PhD, ophthalmologist


A. N. Bessarabov
S. Fyodorov Eye Microsurgery Federal State Institution
Russian Federation
PhD, head of a department ‘information and technologies’


L. V. Agdarova
S. Fyodorov Eye Microsurgery Federal State Institution
Russian Federation
ophthalmologist


References

1. Zuev V.K., Sterhov A.V., Tumanjan Je.R. [Reverse IOL in myopic cataract surgery].Reversnaya IOL v khirurgii miopicheskikh katarakt. [Ophthalmosurgery]. Oftal'mokhirurgiya. 1997;4:21-27. (in Russ.)

2. Zuev V.K., Tumanjan Je.R., Sorokoletov G.V., at all. [Soft reverse-M IOL in cataract surgery in high myopia (preliminary report)]. Myagkaya «reversnaya — M» IOL v khirurgii katarakty pri miopii vysokoy stepeni (predvaritel'noe soobshchenie). [Ophthalmosurgery]. Oftal'mokhirurgiya. 2012;3:26-29. (in Russ.)

3. Sorokoletov G.V., Zuev V.K., Tumanjan Je.R. [Frequency of secondary cataract development in pseudophakic eyes with posterior chamber IOL of current designs in case of axial myopia]. Chastota razvitiya vtorichnoy katarakty v artifakichnykh glazakh s sovremennymi modelyami zadnekamernykh IOL pri osevoy miopii. [Ophthalmosurgery]. Oftal'mokhirurgiya. 2013;2:28-31. (in Russ.)

4. Halili I, Mutlu FM, Erdurman FC at al. Influence of capsular tension ring on posterior capsule opacification in myopic eyes. Indian J Ophthalmol. 2014;62(3):311-315.

5. Gonzalez-Martin-Moro J., Gonzalez-Lopez J.J., Gomez-Sanz F. Posterior capsule opacification, capsular bag distension syndrome, and anterior capsular phimosis: A retrospective cohort study. Arch Soc Esp Oftalmol. 2015;90(2):69-75.

6. Schriefl S.M., Menapaсe R., Stifter E. Posterior capsule opacification and neodymium: YAG laser capsulotomy rates with 2 microincision intraocular lenses: Four-year results. J Cataract Refract Surg. 2015;41(5):956-963.

7. Zhao Y., Li J., Lu W., at al. Capsular adhesion to intraocular lens in highly myopic eyes evaluated in vivo using ultralong-scan-depth optical coherence tomography. Am J Ophthalmol. 2013;155(3):484-491.

8. Kuznetsov S.L., Galeev T.R., Silnova T.V. [Toward the aspects of posterior capsular opacification development in pseudophakia with plate haptic lenses]. K aspektam razvitiya vtorichnoy katarakty pri artifakii linzami s ploskostnoy gaptikoy. [Ophthalmosurgery]. Oftal'mokhirurgiya. 2011;2:64-68. (in Russ.)

9. Tereshchenko Y.A., Sorokin E.L., Belonozhenco Y.V. [Clarification of interrelations between implanted intraocular lenses of various materials and options of opacity formation in the posterior capsule after phacoemulsification of senile cataract]. Vyyasnenie vzaimosvyazey mezhdu implantiruemymi intraokulyarnymi linzami iz razlichnykh materialov i variantami formirovaniya pomutneniy zadney kapsuly khrustalika posle fakoemul'sifikatsii vozrastnoy katarakty. [Ophthalmosurgery]. Oftal'mokhirurgiya. 2014;4:30-34. (in Russ.)

10. Jashinskas V.P., Zhemajtene R., Barzdzhjuskas V. [Secondary cataract and IOL type and the shape of its optic part]. Issledovanie zavisimosti razvitiya vtorichnoykatarakty ot vida IOL i formy ee opticheskoy chasti. [Annals of ophthalmology]. Vestnik oftal'mologii. 2005;1:13-16 (in Russ.)

11. Ashokkumar V., Rajesh N., Peter J., at al. Three-hundred-sixty degree barrier effect of a square-edged and an enhanced-edge intraocular lens on centripetal lens epithelial cell migration. Two-year results. J Cataract Refract Surg. 2007;33:81-87.

12. Cheng J., Wey R., Cai J., at al. Efficacy of different intraocular lens materials and optic lens designs in preventing posterior capsular opacification: a meta-analysis. Am J Ophthalmol. 2007;143(3):428-436.

13. Peng Q., Visessook N., Apple D., at al. Surgical prevention of posterior capsule opacification. Part 3: intraocular burrier lens effect as a second line of defense. J Cataract Refract Surg. 2000; 26:198-213.

14. Peter N., Liliana W., Surekha M., at al. Pathology of 219 human cadaver eyes with 1-piece or 3-piece hydrophobic acrylic intraocular lenses: Capsular bag opacification and sites of square-edged barrier breach. J Cataract Refract Surg. 2011;37:923-930.

15. Sacu S., Findl O., Menapace R., at al. Influence of optic edge design, optic material, and haptic design on capsular bend configuration. J Cataract Refract Surg. 2005;31:1888-1894.

16. Shah A., Spalton D., Gilbert C., at al. Effect of intraocular lens edge profile on posterior capsule opacification after extracapsular cataract surgery in a developing country. J Cataract Refract Surg. 2007;33:1259-1266.

17. Surekha M., Liliana W., Peter N., at al. Pathology of 157 human cadaver eyes with round-edged or modern square-edged silicone intraocular lenses: Analyses of capsule bag opacification. J Cataract Refract Surg. 2011;37:740-748.

18. Sorokoletov G.V., Zuev V.K., Tumanjan Je.R. [A posterior capsule opacification dynamic rate in artificial eyes with modern models of intraocular lenses]. Dinamika chastoty razvitiya vtorichnoy katarakty v artifakichnykh glazakh s sovremennymi modelyami zadnekamernykh IOL. [Cataract and refractive surgery]. Kataraktal'naya i refraktsionnaya khirurgiya. 2014;2:23-26. (in Russ)

19. Abhay V., Shetal R., Alpesh S., at al. Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lenses. J Cataract Refract Surg. 2011;37:1050-1059.

20. Kahraman G., Amon M., Ferdinaro C., at al. Intraindividual comparative analysis of capsule opacification after implantation of 2 single-piece hydrophobic acrylic intraocular lenses models: Three-year follow-up. J Cataract Refract Surg. 2015;41(5):990-996.

21. Takeshi I., Yutarou N., Brian O., at al. Hydrophobic versus double-squareedged hydrophilic foldable acrylic intraocular lens: Effect on posterior capsule opacification. J Cataract Refract Surg. 2011;37:1060-1068.

22. Jorge Pde A., Jorge D., Ventura C.V., at al. Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a four year follow-up study. Arq Bras Oftalmol. 2014;77(4):222-224.

23. Hollic E., Spalton D., Ursell P., et al. The effect of polymethylmethacrylate, silicone and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. Ophthalmology. 1999;106(1):49-54.


Review

For citations:


Sorokoletov G.V., Zuev V.K., Tumanjan J.R., Gerlyak F.M., Veshhikova V.N., Bessarabov A.N., Agdarova L.V. Influence of Intraocular Lens Material and Eye Axial Length on Posterior Capsule Opacification Dynamic Rate and Frequency. Ophthalmology in Russia. 2016;13(4):247-251. (In Russ.) https://doi.org/10.18008/1816-5095-2016-4-247-251

Views: 1407


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1816-5095 (Print)
ISSN 2500-0845 (Online)