Preview

Ophthalmology in Russia

Advanced search

Clinical features of removing phakic intraocular lenses in cataract at high myopia

https://doi.org/10.18008/1816-5095-2012-4-31-35

Abstract

Purpose: Development and an assessment of efficiency of a technique of phakic intraocular lenses (FIOL) at cataract phacoemul- sification.
Methods: 25 FIOL, a pupillary lens RSC-3, a posterior chamber lens, production of MNtK, Russia, and posterior chamber lens ICL S4 StAAR were removed. Before complex surgical intervention (FIOL + phacoemulsification) were carried out standard ophthalmo- logic examination, and also automatic detection of density of endothelial cells.
Results: the developed technique of removal of FIOL included subconjunctival anesthesia, formation of a corneal tunnel, filling of the anterior chamber viscoelastic, FIOL mobilization, removal of the bottom haptic element in the anterior chamber, removal of the top haptic element in the of anterior chamber, FIOL removal. In the early postoperative period in 8% transitory hypertensia was observed, in one case (4%) cornea hypostasis developed. In 92.4% of cases of the maximal visual acuity with correction was corresponded to the planned. Loss of endothelial cells after operation made 4.8% that in full corresponds to standard loss of cells after not complicated phacoemulsification.
Conclusion: the technique of removal of FIOL developed as part of this research allows enough effectively and to carry out safely
to patients surgical treatment of the complicated cataract with a phakic intraocular lenses explantation.

About the Authors

M. E. Konovalov
ФГБОУ ДПО ИПК ФМБА России, Москва
Russian Federation


E. M. Molokotin
ФГБОУ ДПО ИПК ФМБА России, Москва, Россия
Russian Federation


References

1. Buhren J., Kohnen T. Antvendung der wellenfrontanalyse in klinik und wissen- schaft vom irrigularen astigmatismus zu aberrationen hoher ordnung // Oph- thalmologe. — 2007. — Vol. 104. — P. 1007‐1008.

2. Koivula A., Kudelberg M. Optical cogerence tomography of the anterior segment in eyes with phakic refractive lenses // Ophthalmology. — 2007. — Vol. 114. — P. 2031‐2037.

3. Maroccos R., Vaz F., Marinho A., et al. Blendempfindlichkeit und halos nach pha- kic IOL — operation zur behandlung einer hohen myopie // Ophthalmologe. — 2001. — Vol. 98. — P. 1055‐1059.

4. Menezo J. L., Avino J. A., Cisneros A., et al. // Iris claw phakic intraocular lens for high myopia // J Refract Surg. — 2007. — Vol. 13. — P. 545‐555.