Single-step primary open-angle glaucoma and complicated cataract surgery using modified technique of stainless steel Glaucoma Filtration Device implantation

https://doi.org/10.18008/1816-5095-2013-3-9-12

Abstract

Purpose: To analyze the efficacy of novel technique of primary open-angle glaucoma (POAG) and complicated cataract surgery that combines phacoemulsification and modified stainless steel Glaucoma Filtration Device implantation.


Methods: 34 patients (38 eyes) with POAG and complicated cataract were included in the study. Phacoemulsification with Glaucoma Filtration Device implantation using improved technique (i.e., with additional collagen glaucoma drainage implantation and posterior scleral implantation) was performed.


Results: Following phacoemulsification with Glaucoma Filtration Device implantation using modified technique, IOP was decreased by 43 % in a month and remains stable in a year while visual acuity improved almost 5 times in a year.


Conclusion: Phacoemulsification with Glaucoma Filtration Device implantation using modified technique provides adequate IOP reduction and highest possible functional results in early and late post-op period.

About the Authors

I. L Bessonov
Центр микрохирургии «ОКУЛЮС»
Russian Federation


J. A. Gusev
ФГБУЗ КБ 86 ФМБА России
Russian Federation


V. N. Trubilin
ФГБОУ ДПО ИПК ФМБА России
Russian Federation


S. M. Makkaeva
ФГБУЗ КБ 86 ФМБА России
Russian Federation


References

1. Еричев В. П., Мухаммед А. С. Одномоментная экстракция катаракты с антиглаукоматозным компонентом // Избранные вопросы офтальмологии: Межрегин. научно-практ. конф., посвященная 30‑летию Самарской офтальмологической больницы: Сб. тез. — Самара, 1994. — С. 41‑42.

2. Киселева О. А., Филиппова О. М., Бессмертный А. М. Мини-шунт Ex-PRESS —новые возможности микроинвазивной хирургии глаукомы // Рос. Офтальмол. Журн. — 2010. — Т.3. — № 4. — С. 19‑24.

3. Хасанова Н. Х., Амирова Ф. С. Вариант сочетания антиглаукоматозной операции и экстракции катаракты роговичным разрезом // Избр. вопросы офтальмол.: Межрегиональн. науч.‑практ. конф.: Тез. — Самара, 1994. — С. 122‑123.

4. Parker J. S., Gollamudi S., John G. et al. Combined trabeculectomy, cataract extraction,and foldable lens implantation // J. Cataract Refract. Surg. — 1992. —Vol. 18. — No. 6. — P. 582‑585.

5. Traverso C. E., De Feo F., Messas-Kaplan A. et al. Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification // Br. J. Ophthalmol. — 2005. — Vol. 89. — No. 4. — P. 425‑429.

6. Vass C., Menapace R. Surgical strategies in patients with combined cataract and glaucoma // Curr. Opin. Ophthalmol. — 2004. — Vol. 15. — No. 1. — P. 61‑66.


Review

For citations:


Bessonov I.L., Gusev J.A., Trubilin V.N., Makkaeva S.M. Single-step primary open-angle glaucoma and complicated cataract surgery using modified technique of stainless steel Glaucoma Filtration Device implantation. Ophthalmology in Russia. 2013;10(3):9-12. (In Russ.) https://doi.org/10.18008/1816-5095-2013-3-9-12